subject
Engineering, 05.05.2020 05:35 mccdp55

The purpose of this laboratory is to introduce to you a particular method for simulating processes that occur on the cellular and molecular level within cells. The laboratory is a computer simulation laboratory, utilizing a program called SPICE. This is an acronym for Simulation Program with Integrated Circuit Emphasis. The program was developed by electrical engineers to simulate complicated electrical circuits. Now how could we expect to simulate biological systems using an electrical circuit simulator?

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Apump is used to circulate hot water in a home heating system. water enters the well-insulated pump operating at steady state at a rate of 0.42 gal/min. the inlet pressure and temperature are 14.7 lbf/in.2, and 180°f, respectively; at the exit the pressure is 60 lbf/in.2 the pump requires 1/15 hp of power input. water can be modeled as an incompressible substance with constant density of 60.58 lb/ft3 and constant specific heat of 1 btu/lb or. neglecting kinetic and potential energy effects, determine the temperature change, in °r, as the water flows through the pump.
Answers: 1
question
Engineering, 04.07.2019 18:10
An air conditioning system consist of a 5 cm diameter pipe, operating at a pressure of 200 kpa. the air initially enters the pipe at 15°c with a velocity of 20 m/s and relative humidity of 80%. if the heat supply throughout the process is 960 w, determine the relative humidity and the temperature at the outlet
Answers: 3
question
Engineering, 04.07.2019 18:10
Apipe with an outside diameter of 15 cm is exposed to an ambient air and surrounding temperature of -20°c. the pipe has an outer surface temperature of 65°c and an emissivity of 0.85. if the rate of heat loss from the pipe surface is 0.95 kw per meter of length, the external convective heat transfer coefficient (h) is: (a) 12.5 w/m"k (b) 18.6 w/mk (c) 23.7 w/mk (d) 27.9 w/mk (e) 33.5 w/mk
Answers: 1
question
Engineering, 04.07.2019 18:20
Derive the correction factor formula for conical nozzle i=-(1+ cosa) and calculate the nozzle angle correction factor for a nozzle whose divergence hal-fangle is 13 (hint: assume that all the mass flow originates at the apex of the cone.
Answers: 3
You know the right answer?
The purpose of this laboratory is to introduce to you a particular method for simulating processes t...
Questions
question
Health, 03.05.2021 22:00
question
Mathematics, 03.05.2021 22:00
question
History, 03.05.2021 22:00
question
Mathematics, 03.05.2021 22:00
question
Mathematics, 03.05.2021 22:00
question
Mathematics, 03.05.2021 22:00
question
Mathematics, 03.05.2021 22:00
question
Mathematics, 03.05.2021 22:00
question
Computers and Technology, 03.05.2021 22:00
Questions on the website: 13722367