subject
Engineering, 02.06.2020 23:58 Geo777

The viscosity of liquids can be measured through the use of rotating-cylinder viscosimeter of
the type shown in Figure 2. In this device, the outer cylinder is fixed and the inner cylinder
is rotated with an angular frequency, ω. The torque, T, required to maintain a constant
ω is measured and the dynamic viscosity, µ, is calculated from these two measurements.
By neglecting end effects and assuming the velocity distribution in the gap to be linear, an
equation relating µ, ω, T, l, R0, and Ri may be written as
2πRi
3lω T = µ. R0 − Ri
a) Derive this equation and show that it is dimensionally correct.
The following torque-angular velocity data were obtained with a rotating-cylinder viscosimeter with R0 = 6.0 cm, Ri = 5.9 cm, and l = 25.0 cm:
Torque (N m· ) 0.178 0.353 0.536 0.715 0.880 1.066
Angular velocity 1.0 2.0 3.0 4.0 5.0 6.0
(rad/s)
b) Give your best estimate of the viscosity, µ.
c) Indicate the accuracy of this estimate.
d) Using Appendix B in Young et al.’s book, what fluid do you think was used if the temperature of the fluid was 15oC.

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 16:10
The force on a cutting tool are 2600n vertically downward and 2100 horizontal. determine the resultant force acting on the tool and the angle at which it acts.
Answers: 1
question
Engineering, 04.07.2019 18:10
At 12 noon, the count in a bacteria culture was 400; at 4: 00 pm the count was 1200 let p(t) denote the bacteria cou population growth law. find: (a) an expression for the bacteria count at any time t (b) the bacteria count at 10 am. (c) the time required for the bacteria count to reach 1800.
Answers: 1
question
Engineering, 04.07.2019 18:20
Inadequate stores control is not an obstacle to effective work order system. (clo4) a)-true b)-false
Answers: 3
question
Engineering, 04.07.2019 18:20
Water vapor initially at 10 bar and 400 °c is contained within a piston-cylinder assembly. the water lost heat to the surrounding according to isochoric (iso-volumetric) process until its temperature is 150 °c. the water is then condensed isothermally to saturated liquid. for the water as a system, calculate the work in kj/kg
Answers: 2
You know the right answer?
The viscosity of liquids can be measured through the use of rotating-cylinder viscosimeter of
...
Questions
question
Chemistry, 19.01.2021 16:50
question
Mathematics, 19.01.2021 16:50
question
Physics, 19.01.2021 16:50
Questions on the website: 13722359