subject
Engineering, 15.07.2020 01:01 Evixie84

Add the following methods to the ArrayBoundedStack class, and create a test driver for each to show that they work correctly. In order to practice your array related coding skills, code each of these methods by accessing the internal variables of the ArrayBoundedStack, not by calling the previously defined public methods of the class. A. String toString()—creates and returns a string that correctly represents the current stack. Such a method could prove useful for testing and debugging the class and for testing and debugging applications that use the class. Assume each stacked element already provided its own reasonable toString method.
B. int size()—returns a count of how many items are currently on the stack. Do not add any instance variables to the ArrayBoundedStack class in order to implement this method.
C. void popSome(int count)—removes the top count elements from the stack; throws StackUnderflowException if there are less than count elements on the stack.
D. boolean swapStart()—if there are less than two elements on the stack returns false; otherwise it reverses the order of the top two elements on the stack and returns true.
E. T poptop( )—the "classic" pop operation, if the stack is empty it throws StackUnderflowException; otherwise it both removes and returns the top element of the stack.

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Refrigerant 134a enters an insulated compressor operating at steady state as saturated vapor at -26°c with a volumetric flow rate of 0.18 m3/s. refrigerant exits at 9 bar, 70°c. changes in kinetic and potential energy from inlet to exit can be ignored. determine the volumetric flow rate at the exit, in m3/s, and the compressor power, in kw.
Answers: 1
question
Engineering, 04.07.2019 18:10
Apipe with an outside diameter of 15 cm is exposed to an ambient air and surrounding temperature of -20°c. the pipe has an outer surface temperature of 65°c and an emissivity of 0.85. if the rate of heat loss from the pipe surface is 0.95 kw per meter of length, the external convective heat transfer coefficient (h) is: (a) 12.5 w/m"k (b) 18.6 w/mk (c) 23.7 w/mk (d) 27.9 w/mk (e) 33.5 w/mk
Answers: 1
question
Engineering, 04.07.2019 18:10
Condition monitoring is a major component of. (clo4) a)- predictive maintenance. b)-preventive maintenance c)-proactive maintenance d)-reactive maintenance.
Answers: 1
question
Engineering, 04.07.2019 18:10
Calculate the bore of a cylinder that has a stroke of 18 inches and an extension time of 6 seconds at a flow rate of 4 gal/min.
Answers: 3
You know the right answer?
Add the following methods to the ArrayBoundedStack class, and create a test driver for each to show...
Questions
question
Spanish, 19.12.2020 08:30
question
Biology, 19.12.2020 08:30
question
Spanish, 19.12.2020 08:30
Questions on the website: 13722362