A company is about to establish an industrial refrigeration plant in an area where there is difficulty in accessing large quantities of water. During the design process of the refrigeration

plant, you have been tasked to select a suitable condenser for application considering factors

such as maintenance, cost, efficiency, effectiveness and size. What type of condenser will you

select and why?

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Water at 55c flows across a flat plate whose surface temperature is held constant at 95c. if the temperature gradient at the plate's surface for a given value of x is 18 c/mm, find a) local heat transfer coefficient. b) heat flux
Answers: 3
question
Engineering, 04.07.2019 18:10
Carbon dioxide gas expands isotherm a turbine from 1 mpa, 500 k at 200 kpa. assuming the ideal gas model and neglecting the kinetic and potential energies, determine the change in entropy, heat transfer and work for each kilogram of co2.
Answers: 2
question
Engineering, 04.07.2019 19:10
Tom is having a problem with his washing machine. he notices that the machine vibrates violently at a frequency of 1500 rpm due to an unknown rotating unbalance. the machine is mounted on 4 springs each having a stiffness of 10 kn/m. tom wishes to add an undamped vibration absorber attached by a spring under the machine the machine working frequency ranges between 800 rpm to 2000 rpm and its total mass while loaded is assumed to be 80 kg a) what should be the mass of the absorber added to the machine so that the natural frequency falls outside the working range? b) after a first trial of an absorber using a mass of 35 kg, the amplitude of the oscillation was found to be 10 cm. what is the value of the rotating unbalance? c) using me-3.5 kg.m, find the optimal absorber (by minimizing its mass). what would be the amplitude of the oscillation of the absorber?
Answers: 3
question
Engineering, 05.07.2019 23:20
Which one of the following faults cause the coffee in a brewer to keep boiling after the brewing cycle is finished? a. an open circuit in the heating element b. a short circuit at the terminals c. welded contacts on the thermostat d. a leak around the gasket
Answers: 3
You know the right answer?
A company is about to establish an industrial refrigeration plant in an area where there is difficu...
Questions
question
Physics, 29.03.2021 18:50
question
Mathematics, 29.03.2021 18:50
question
Mathematics, 29.03.2021 18:50
question
Mathematics, 29.03.2021 18:50
question
Mathematics, 29.03.2021 18:50
question
Mathematics, 29.03.2021 18:50
Questions on the website: 13722360