subject
Engineering, 31.07.2020 17:01 romanbattistelli23

Humid air is to be conditioned in a constant pressure process at 1 atm from 398C dry bulb and 50 percent relative humidity to 178C dry bulb and 10.88C wet bulb. The air is first passed over cooling coils to remove all of the moisture necessary to achieve the final moisture content and then is passed over heating coils to achieve the final state. (a) Sketch the psychometric diagram for the process.
(b) Determine the dew point temperature of the mixture at the inlet of the cooling coils and at the inlet of the heating coils.
(c) What is the net heat transfer for the entire process for this process, in kJ/kg dry air?

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:20
Determine the damped natural frequencies and the steady state response of a decoupled damped forced two degrees of freedom system. 10ä1 + 2q1 20q1 10 cos t; 10q2 +4q2 + 40q2 10 cos t
Answers: 3
question
Engineering, 04.07.2019 18:20
For each of the following process: a) sketch the p-v diagram, b)sketch t-s diagram, c) sketch t-v diagram, d) sketch the boundary work on one of the diagrams (a, b or c) and e) sketch the reversible heat transfer on one of the diagrams (a, b or c): 1- isobaric process from compressed liquid to superheated vapor 2- isothermal process from compressed liquid to superheated vapor 3- isentropic process from compressed liquid to superheated vapor
Answers: 3
question
Engineering, 04.07.2019 19:10
Arigid tank contains 10 kg of air at 137 kpa (abs) and 21°c. more air is added to the tank until the pressure and temperature rise to 242 kpa (abs) and 32°c, respectively. determine the amount of air added to the tank. [r-0.287 kj/kg k]
Answers: 3
question
Engineering, 04.07.2019 19:20
Apiping systems consists of 6 m of 6-std type k and 12 m of 4-std type k, both drawn copper tubing. the system conveys ethylene glycol at a rate of 0.013 m3/s. the pressure drop across the system is to be calculated. there are two 90° elbows in the 6-in pipe, a reduction from the 6-in pipe to the 4-in pipe and four 90° elbows in the 4-in pipe. all fittings are soldered (same as flanged) and regular. the inlet and outlet of the system are at the same height.
Answers: 1
You know the right answer?
Humid air is to be conditioned in a constant pressure process at 1 atm from 398C dry bulb and 50 per...
Questions
question
Mathematics, 16.05.2021 23:50
question
Arts, 16.05.2021 23:50
question
Mathematics, 16.05.2021 23:50
question
English, 16.05.2021 23:50
question
Mathematics, 16.05.2021 23:50
question
English, 16.05.2021 23:50
Questions on the website: 13722363