subject
Engineering, 24.08.2020 01:01 carlosthenoob03

Use the equation given to determine the "theoretical" values of g M / moles H2 (note that "M" is simply the metal, which is either La, Ba, Mn, or Pb). The equation is g metal / moles H2 = mass of metal / (moles H2/moles metal). The unknowns are each one of the following metals - La, Ba, Mn, Pb. Calculate the theoretical values of g M/ moles H2 for each of these metals. In each case, the metal chloride product is identified to the right to help determine the ratio of moles M / moles H2 produced.
g / La moles H2 - ? (LaCi 3 is produced)
g / Ba moles H2 - ? (BaCi 2 is produced)
g / Mn moles H2 - ? (MnCI2 is produced)
g / Pb moles H2 - ? (PbCI 2 is produced)
Write the balanced chemical equation for the reaction between the metals given and HCl (for example, La + HCl > LaCl3 + H2this equation needs to be balanced first). From the balanced chemical equation, you can determine the moles of H2/moles La. Remember that the number of moles is just the number of the coefficient in from of the molecule. For example, if you have 3H + 2O ---> 4H2O, there are 3 moles of H, 2 moles of O, and 4 moles of H2O in that equation. The mass of the metal (La) is just the atomic mass of La obtained from the periodic table.

ansver
Answers: 3

Another question on Engineering

question
Engineering, 03.07.2019 23:20
Two technicians are discussing the intake air temperature (iat) sensor. technician a says that the computer uses the iat sensor as a backup to the engine coolant temperature (ect) sensor. technician b says that the powertrain control module (pcm) will subtract the calculated amount of fuel if the air measures hot. who is correct
Answers: 3
question
Engineering, 04.07.2019 18:10
Air is to be cooled in the evaporator section of a refrigerator by passing it over a bank of 0.8-cm-outer-diameter and 0.4-m-long tubes inside which the refrigerant is evaporating at -20°c. air approaches the tube bank in the normal direction at 0°c and 1 atm with a mean velocity of 4 m/s. the tubes are arranged in-line with longitudinal and transverse pitches of sl- st 1.5 cm. there are 30 rows in the flow direction with 15 tubes in each row. determine (a) the refrigeration capacity of this system and (b) pressure drop across the tube bank. evaluate the air properties at an assumed mean temperature of -5°c and 1 atm. is this a good assumption?
Answers: 1
question
Engineering, 04.07.2019 18:10
For the closed feedwater heater below, feedwater enters state 3 at a pressure of 2000 psia and temperature of 420 °f at a rate of ix10 ibhr. the feedwat extracted steam enters state 1 at a pressure of 1000 psia and enthalpy of 1500 btu/lbm. the extracted er leaves at an enthalpy of 528.7 btu/lbm steam leaves as a saturated liquid. (16) a) determine the mass flow rate of the extraction steam used to heat the feedwater (10) b) determine the terminal temperature difference of the closed feedwater heater
Answers: 3
question
Engineering, 04.07.2019 18:10
Water at 55c flows across a flat plate whose surface temperature is held constant at 95c. if the temperature gradient at the plate's surface for a given value of x is 18 c/mm, find a) local heat transfer coefficient. b) heat flux
Answers: 3
You know the right answer?
Use the equation given to determine the "theoretical" values of g M / moles H2 (note that "M" is sim...
Questions
Questions on the website: 13722363