Three single-phase loads in parallel are supplied from a 1400V (RMS), 60 Hz supply. The loads are as follows: Load 1: Inductive load: 125 kVA, 0.28 power factor Load 2: Capacitive load: 10 kW, 40 kVAR Load 3: Resistive load: 15 kW Find the total kW, kVAR, kVA, and supply power factor. (5 points) Find the capacitive correction (in kVARs) required to improve the power factor to 0.8 and calculate the supply current with this correction in place. (10 points) What is the least current that can service these three loads and how much compensation would it require
Answers: 3
Engineering, 04.07.2019 18:10
Coiled springs ought to be very strong and stiff. si3n4 is a strong, stiff material. would you select this material for a spring? explain.
Answers: 2
Engineering, 04.07.2019 18:10
Afour cylinder four-stroke in-line engine has a stroke of 160mm, connecting rod length of 150mm, a reciprocating mass of 3kg and its firing order is 1-3-4-2. the spacing between cylinders is 100mm. i. show that the engine is in balance with regard to the primary inertia forces and primary 3. a and secondary inertia couples. li determine the out of balance secondary inertia force ii. propose ways of balancing this out of balance force and discuss the challenges that will arise
Answers: 3
Engineering, 04.07.2019 18:10
Assuming compressible flow of air and that the measurements are done at flagstaff a pitot static tube that gives the difference of total and static pressure measures 0.35 m of mercury. what is the velocity of air? assume the temperature to be 300k. (submit your excel or matlab calculation sheet)
Answers: 1
Engineering, 04.07.2019 18:10
What are the two (02) benefits, which may result from a successful implementation of preventive maintenance (pm) program in an organization? (clo3)a)- lean manufacturing b)-overlapping responsibilities c)-the planner is not qualified d)-accurate contractor information e)-reduction in equipment redundancies f)-accurate stores information
Answers: 3
Three single-phase loads in parallel are supplied from a 1400V (RMS), 60 Hz supply. The loads are as...
Health, 16.11.2020 14:00
Chemistry, 16.11.2020 14:00
Mathematics, 16.11.2020 14:00
Geography, 16.11.2020 14:00
Computers and Technology, 16.11.2020 14:00
English, 16.11.2020 14:00
Mathematics, 16.11.2020 14:00
English, 16.11.2020 14:00
Biology, 16.11.2020 14:00
Mathematics, 16.11.2020 14:00
History, 16.11.2020 14:00
Mathematics, 16.11.2020 14:00
Mathematics, 16.11.2020 14:00
Mathematics, 16.11.2020 14:00
Engineering, 16.11.2020 14:00
Computers and Technology, 16.11.2020 14:00
Mathematics, 16.11.2020 14:00