Engineering, 22.10.2020 17:01 syrai1254
A refrigerant expansion valve is located between the condenser and evaporator and controls the flow of fluid into the evaporator, which in turn regulates the entry condition into the compressor. The valve is small, so heat transfer can be neglected. The refrigerant in this system is propane. at the exit of the condenser (entrance to the expansion valve). the properties are Temperature = 30 C, and a saturated liquid. The evaporator pressure (exit of the valve) is at 320 kPa. What is the quality of the flow at the entrance to the evaporator (exit of the valve)? State the quality as a number between 0 and 1, not as a percent.
Answers: 1
Engineering, 04.07.2019 18:10
Ajournal bearing has a journal diameter of 3.250 in with a unilateral tolerance of 20.003 in. the bushing bore has a diameter of 3.256 in and a unilateral tolerance of 0.004 in. the bushing is 2.8 in long and supports a 700-lbf load. the journal speed is 900 rev/min. find the minimum oil film thickness and the maximum film pressure for both sae 20 and sae 20w-30 lubricants, for the tightest assembly if the operating film temperature is 160°f. a computer code is appropriate for solving this problem.
Answers: 3
Engineering, 04.07.2019 18:10
Aturning operation is performed with following conditions: rake angle of 12°, a feed of 0.35 mm/rev, and a depth of cut of 1.1 mm. the work piece is aluminum alloy 6061 with t6 heat treatment (a16061-t6). the resultant chip thickness was measured to be 1.0 mm. estimate the cutting force, fc. use shear stress of 207 mpa and coefficient of friction on the tool face of 0.6.
Answers: 1
Engineering, 04.07.2019 19:10
Ahelical coil spring has a mean diameter of 50 mm, a wire diameter of 5.5 mm and is wound with a pitch of 10 mm. the spring steel has an ultimate strength of 1250 mpa. find the force needed to compress the spring solid and the wire stress in this condition. state whether the spring will return to its initial length.
Answers: 1
Engineering, 04.07.2019 19:20
Brief discuss how the presence of dislocations in crystal structures can be an advantage and a disadvantage to engineer and designers.
Answers: 3
A refrigerant expansion valve is located between the condenser and evaporator and controls the flow...
Computers and Technology, 13.10.2019 11:30
Mathematics, 13.10.2019 11:30
Social Studies, 13.10.2019 11:30
Social Studies, 13.10.2019 11:30
Mathematics, 13.10.2019 11:30
Social Studies, 13.10.2019 11:30
History, 13.10.2019 11:30
Mathematics, 13.10.2019 11:30
Mathematics, 13.10.2019 11:30
English, 13.10.2019 11:30
History, 13.10.2019 11:30