subject
Engineering, 05.11.2020 22:00 parislightbourne77

Describing Projected Growth for Nursery and Greenhouse Managers
Click this link to view O*NET'S Wages and Employment section for Nursery and Greenhouse Managers.
According to O*NET, what is the projected growth for this career between 2016-2026?
O faster than average
O average
O slower than average
little or no change
Done
Intro

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Afull journal bearing has a journal diameter of 27 mm, with a unilateral tolerance of -0.028 mm. the bushing bore has a diameter of 27.028 mm and a unilateral tolerance of 0.04 mm. the l/d ratio is 0.5. the load is 1.3 kn and the journal runs at 1200 rev/min. if the average viscosity is 50 mpa-s, find the minimum film thickness, the power loss, and the side flow for the minimum clearance assembly.
Answers: 1
question
Engineering, 04.07.2019 18:10
Which of the following components of a pid controlled accumulates the error over time and responds to system error after the error has been accumulated? a)- proportional b)- derivative c)- integral d)- on/off.
Answers: 2
question
Engineering, 04.07.2019 19:20
Determine the time of the day and month of the year at which the peak sensible cooling load occurs for a top floor, north-eastern corner room of an office building in durban for the following conditions: floor area: 8 x 8 x 3 m east and north walls: 115 mm face brick (outside), 20 mm air space, 115 mm ordinary brick (inside) with 15 mm plaster roof construction: suspended plasterboard ceiling, 450 mm air space, 150 mm concrete, 75mm screed, waterproofing no heat transfer across other surfaces window area 3x 1,5 m high in north wall only. ordinary glass with venetian blinds. lights and occupants : from 07: 00 to 18: 00 average light density: 25 w/m2 number of occupants : 5 seated, light office work room temperature 24°c
Answers: 3
question
Engineering, 06.07.2019 03:30
The catalogue for a refrigerant 22, four-cylinder, hermetic compressor operating at 29 r/s. a condensing temperature of 40°c and an evaporating temperature of -4°c shows a refrigeration capacity of 115 kw. at this operating point, the motor (its efficiency is 90 percent) draws 34.5 kw. the bore of the cylinders is 87 mm and the piston stroke is 70 mm. the performance data are based on 8°c of sub-cooling of the liquid leaving the condenser. compute (a) the actual volumetric efficiency and (b) the compression efficiency.
Answers: 2
You know the right answer?
Describing Projected Growth for Nursery and Greenhouse Managers
Click this link to view O*NET...
Questions
question
Biology, 10.11.2021 19:10
question
Mathematics, 10.11.2021 19:10
question
English, 10.11.2021 19:10
question
Mathematics, 10.11.2021 19:10
question
Biology, 10.11.2021 19:10
question
Mathematics, 10.11.2021 19:10
question
Arts, 10.11.2021 19:10
question
Mathematics, 10.11.2021 19:10
Questions on the website: 13722363