What relationship is there between the hydraulic system and power, force, energy, resources, and types of energy?

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 18:20
Athin walled concentric tube exchanger is used to cool engine oil from 160°c to 60°c with water that is available at 25°c acting as a coolant. the oil and water flow rates are each at 2 kg/s, and the diameter of the inner tube is 0.5 m and the corresponding value of the overall heat transfer coefficient is 250 w/m2. oc. how long must the heat exchanger be to accomplish the desired cooling? cpwater=4.187 kj/kg-candcpengine el=2.035 kj/kg·°c, oil . 120]
Answers: 1
question
Engineering, 06.07.2019 03:20
Asimply supported beam abc of length l has ab of length hl and second moment of area / and bc of length hl and second moment of area i2. determine the strain energy stored in the beam when it is subject to a vertical load f at its midpoint and the consequential central deflection.
Answers: 2
question
Engineering, 06.07.2019 04:10
Consider a power plant with water as the working fluid that operates on an ideal rankine cycle. it has a net power output of 45mw. superheated steam enters the turbine at 7mpa and 500°c (h=3411.4 kj/kg; s=6.8 kj/kg k) and is cooled in the condenser at a pressure of 10 kpa by running cooling water from a lake through the tubes of the condenser at a rate of 2000 kg/s. (a) show the cycle on a t-s diagram (a right schematic is fine - you do not need to calculate the temperatures at each point); (b)-determine the work done by the turbine and the pump in kj/kg; (c)-the mass flow rate of water used by the power plant; (d)-the thermal efficiency of the cycle; (e)-the temperature rise of the cooling water. assume the cooling water is incompressible with cp 4.18 kj/kg°c.
Answers: 3
question
Engineering, 06.07.2019 05:30
A1.5-in-diameter bar has been machined from an aisi 1050 cold-drawn bar. this part is withstand a fluctuating tensile stress varying from 0 to 18.0 kpsi. because of the ends, and the fill radius, a fatigue stress-concentration factor ky is 1.6 for 10 or larger life. the fully correcte endurance limit is s 34 kpsi, sat= 100 kpsi and s, 84 kpsi. find the factor of safety guardin against fatigue, using the modified goodman fatigue line and first-cycle yielding
Answers: 2
You know the right answer?
What relationship is there between the hydraulic system and power, force, energy, resources, and typ...
Questions
question
Mathematics, 24.06.2021 04:10
question
Mathematics, 24.06.2021 04:10
question
Physics, 24.06.2021 04:10
question
Mathematics, 24.06.2021 04:10
Questions on the website: 13722362