Consider flow of a very low Pr number fluid (say Pr = 0.005) on a heated flat plate. The plate temperature is kept constant at Ts. The freestream velocity is Uinf and freestream temperature is Tinf. Starting with the 2D steady state energy equation, simplify it for this low Pr flow with clear justification for the simplifications. Perform an order of magnitude analysis on the energy equation to develop an expression for local Nu for this type of flow.

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 19:10
What is a monomer? how do they form a ploymer from the view point of chemical bonding?
Answers: 1
question
Engineering, 04.07.2019 19:10
An electric kettle is made out of stainless steel, weighs two pounds (when empty) and is equipped with a heating element that consumes 2 kw of electricity. assuming that the water and the kettle are at the same uniform temperature at any moment of time, calculate the shortest possible time to bring 2 quarts of water from room temperature to the onset of boiling
Answers: 2
question
Engineering, 06.07.2019 03:10
Tom is having a problem with his washing machine. he notices that the machine vibrates violently at a frequency of 1500 rpm due to an unknown rotating unbalance. the machine is mounted on 4 springs each having a stiffness of 10 kn/m. tom wishes to add an undamped vibration absorber attached by a spring under the machine the machine working frequency ranges between 800 rpm to 2000 rpm and its total mass while loaded is assumed to be 80 kg. a) what should be the mass of the absorber added to the machine so that the natural frequency falls outside the working range? b) after a first trial of an absorber using a mass of 35 kg, the amplitude of the oscillation was found to be 10 cm. what is the value of the rotating unbalance? c) using me-3.5 kg.m, find the optimal absorber (by minimizing its mass). what would be the amplitude of the oscillation of the absorber?
Answers: 1
question
Engineering, 06.07.2019 04:10
Ir at sea level and 30Β°c and 50% relative humidity flows at a rate of 1 kg/s through a cooling coil that has an apparatus dewpoint of 10Β°c. the air leaves the coil at 15Β°c. determine the following: 3.1)- relative humidity of the air leaving the coil; 3.2)- moisture content of the air leaving the coil; 3.3)- sensible heat factor; 3.4)- total heat transfer rate; 3.5)- sensible heat transfer rate 3.6)- latent heat transfer rate
Answers: 1
You know the right answer?
Consider flow of a very low Pr number fluid (say Pr = 0.005) on a heated flat plate. The plate tempe...
Questions
Questions on the website: 13722367