Discuss the relative merits of using a proportional plus integral controller over purely proportional control in modifying system performance? [5] A second-order type-0 system with transfer function

G(s)=1/(s+1)(s+5)

is to be compensated using the controller

Gc(s)=1+K/s

under unity feedback. For the overall feedback system:

(i) Derive the system characteristic equation [5]
(ii) Obtain the value of integral gain K for which the system becomes unstable [5]
(iii) Discuss how K can be designed to meet relative stability criteria.

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Refrigerant 134a enters an insulated compressor operating at steady state as saturated vapor at -26°c with a volumetric flow rate of 0.18 m3/s. refrigerant exits at 9 bar, 70°c. changes in kinetic and potential energy from inlet to exit can be ignored. determine the volumetric flow rate at the exit, in m3/s, and the compressor power, in kw.
Answers: 1
question
Engineering, 04.07.2019 18:10
Different types of steels contain different elements that alter the characteristics of the steel. for each of the following elements, explain what the element does when alloyed with steel.
Answers: 2
question
Engineering, 04.07.2019 19:10
Apressure vessel with an r/t 20 cannot be treated as thin walled vessel. a)-trune b)- false
Answers: 3
question
Engineering, 06.07.2019 04:10
An array of m-50 thermoelectric modules is installed on the exhaust of a sports car. each module has an effective seebeck coefficient of sp of 0.143 5vk and an internal electrical resistance of r.-4 ? in addition, : (15 points each module is of width w 60mm and contains n=100 pairs of semiconducting pellets. each pellet hasan overall length of 2l-5mm and a cross-sectional area as 1.2 x 10'm and is characterized by a thermal conductivity of kpl2w rnk. the hot side of each module is exposed to exhaust gases at·p650c with hia4ow rrk while the osite side of each module is cooled by pressurized water at surface) and 156 °c (at the cool surface). 11s c with h: -500w/m'k. the modules are wired n series and the load resistance is r d=400ohm .the module surface temperatures, t, and ts are 183 "c (at the hot surface and 156c (at the cool surface) a)-draw a schematic of this scenario and label all parts. a. b. if the induced current, i, is 0.15 amps, what is the total power (pa) for one module? c. what is the total power harvest from the exhaust with all 50 modules?
Answers: 2
You know the right answer?
Discuss the relative merits of using a proportional plus integral controller over purely proportiona...
Questions
Questions on the website: 13722363