subject
Engineering, 01.03.2021 19:30 katiebotts18

Some extremely hazardous materials used in welding operations include: Fluorine compounds
Metals containing lead
Cadmium-containing filler metals
All of the above

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
A-mn has a cubic structure with a0 0.8931 nm and a density of 7.47 g/cm3. b-mn has a different cubic structure, with a0 0.6326 nm and a density of 7.26 g/cm3. the atomic weight of manganese is 54.938 g/mol and the atomic radius is 0.112 nm. determine the percent volume change that would occur if a-mn transforms to b-mn.
Answers: 2
question
Engineering, 04.07.2019 19:10
Ahelical coil spring has a mean diameter of 50 mm, a wire diameter of 5.5 mm and is wound with a pitch of 10 mm. the spring steel has an ultimate strength of 1250 mpa. find the force needed to compress the spring solid and the wire stress in this condition. state whether the spring will return to its initial length.
Answers: 1
question
Engineering, 04.07.2019 19:20
Acommercial grade cubical freezer, 4 m on a side, has a composite wall consisting of an exterior sheet of 5.0-mm thick plain carbon steel (kst= 60.5 w/m k), an intermediate layer of 100-mm thick polyurethane insulation (kins 0.02 w/m k), and an inner sheet of 5.0- mm thick aluminium alloy (kal polyurethane insulation and both metallic sheets are each characterized by a thermal contact resistance of r 2.5 x 104 m2 k/w. (a) what is the steady-state cooling load that must be maintained by the refrigerator under conditions for which the outer and inner surface temperatures are 25°c and -5°c, respectively? (b) for power saving purpose, which wall material should be increased/reduced in. thickness in order to reduce 50% of the cooling load found in part (a)? redesign the thickness of the proposed material. 177 w/m-k). adhesive interfaces between the q=575.93 w
Answers: 2
question
Engineering, 06.07.2019 03:30
An ammonia compressor has a 5% clearance volume and displacement rate of 80 l/s and pumps against a condensing temperature of 40°c. for two different temperatures of -10°c and 10°c, compute the mass flow rate of refrigerant assuming the clearance volumetric efficiency applies. discharge specific volume corresponding to-10°c and 10°c are 112.5 l/kg and 95 l/kg, respectively.
Answers: 2
You know the right answer?
Some extremely hazardous materials used in welding operations include: Fluorine compounds
Met...
Questions
question
Mathematics, 26.03.2021 20:30
question
Chemistry, 26.03.2021 20:30
question
Mathematics, 26.03.2021 20:30
Questions on the website: 13722363