subject
Engineering, 02.03.2021 14:00 dlr1628

8.2 Measurement Methods 8.2.1 Direct Injection of Solvent
The solvent is injected into the sample in a continuous process. The sample is held in a rubber
sleeve thus forcing the flow to be uniaxial.
8.2.2 Centrifuge Flushing
A centrifuge which has been fitted with a special head sprays warm solvent onto the sample.
The centrifugal force then moves the solvent through the sample. The used solvent can be
collected and recycled.
8.2.3 Gas Driven Solvent Extraction
The sample is placed in a pressurized atmosphere of solvent containing dissolved gas. The
solvent fills the pores of sample. When the pressure is decreased, the gas comes out of
solution, expands, and drives fluids out of the rock pore space. This process can be repeated
as many times as necessary.
8.2.4 Soxhlet Extraction
A Soxhlet extraction apparatus is the most common method for cleaning sample, and is
routinely used by most laboratories. As shown in Figure 8.1, toluene is brought to a slow boil
in a Pyrex flask; its vapors move upwards and the core becomes engulfed in the toluene
vapors (at approximately 110°C). Eventual water within the core sample in the thimble will
be vaporized. The toluene and water vapors enter the inner chamber of the condenser, the
cold water circulating about the inner chamber condenses both vapors to immiscible liquids.
Recondensed toluene together with liquid water falls from the base of the condenser onto the
core sample in the thimble; the toluene soaks the core sample and dissolves any oil with
which it come into contact. When the liquid level within the Soxhlet tube reaches the top of
the siphon tube arrangement, the liquids within the Soxhlet tube are automatically emptied bya siphon effect and flow into the boiling flask .the toluene is then ready to start another cycle. A complete extraction may take several days to several weeks in the case of low:API gravity crude or presence of heavy residual hydrocarbon deposit within the core low permeability rock may also require a long extraction time

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Water at 70°f and streams enter the mixing chamber at the same mass flow rate, determine the temperature and the quality of the exiting stream. 0 psia is heated in a chamber by mixing it with saturated water vapor at 20 psia. if both streams enters the mixing chamber at the same mass flow rate, determine the temperature and the quality of the existing system.
Answers: 2
question
Engineering, 04.07.2019 18:10
Thermal stresses are developed in a metal when its a) initial temperature is changed b) final temperature is changed c) density is changed d) thermal deformation is prevented e) expansion is prevented f) contraction is prevented
Answers: 2
question
Engineering, 04.07.2019 18:10
Manometers are good examples of measuring instruments, nowadays they are not as common as before. a)-capacitive probe gauges b)-gravitational gauges deformation ) gauges d)-digital gauges
Answers: 1
question
Engineering, 04.07.2019 18:10
Ahot wire operates at a temperature of 200°c while the air temperature is 20°c. the hot wire element is a tungsten wire of 5 um diameter and 2 mm in length. plot using excel current, heat transfer and heat generated by the wire for air velocity varying from 1-10 m/s in steps of lm/s? matlab the sensor voltage output, resistance, or assume nu 0.989 re033pr13 take air properties at tr (200°c20°c)/2 = 110°c properties of tungsten: c 0.13 kj/kg.k 3 p 19250 kg/m k (thermal conductivity) = 174 w/m.k
Answers: 2
You know the right answer?
8.2 Measurement Methods 8.2.1 Direct Injection of Solvent
The solvent is injected into the sam...
Questions
question
Mathematics, 05.07.2019 05:00
question
History, 05.07.2019 05:00
question
World Languages, 05.07.2019 05:00
Questions on the website: 13722359