In each of the cases below, (a) through (e), you will need to explain why you chose the answer you did. The elementary isomerization exothermic reaction A>B
<
is carried out isothermally at 400 K in a PBR in which pressure drop plays a role, with alpha = 0.001 kg^-1. Currently. 50% conversion is achieved. The equilibrium constant at this temperature is 3.0.
a. For a fixed mass flow rate m, if the reactor diameter is increased by a factor of 4, the conversion will
(i) X > 0.5
(ii) X < 0.5
(iii) X = 0.5
(iv) insufficient information to tell.
b. For a fixed mass flow rate m., the equilibrium conversion is
(i) X_e = 0.5
(ii) X_e = 0.667
(iii) X_e = 0.75
(iv) insufficient information to tell
c. For a fixed mass flow rate m, if the reactor diameter is increased by a factor of 2 the equilibrium conversion X_e will
(i) increase
(ii) decrease
(iii) remain the same
(iv) insufficient information to tell
d. For a fixed mass flow rate m., if the particle size is increased, the equilibrium conversion
(i) increase
(ii) decrease
(iii) remain the same
(iv) insufficient information to tell
d. For a fixed mass flow rate m., if the particle size is the conversion will
(i) increase
(ii) decrease
(iii) remain the same
(iv) insufficient information to tell

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Condition monitoring is a major component of. (clo4) a)- predictive maintenance. b)-preventive maintenance c)-proactive maintenance d)-reactive maintenance.
Answers: 1
question
Engineering, 04.07.2019 18:20
Along 8-cm diameter steam pipe whose external surface temperature is 900c connects two buildings. the pipe is exposed to ambient air at 70c with a wind speed of 50 km/hr blowing across the pipe. determine the heat loss from the pipe per unit length. (b) air at 500c enters a section of a rectangular duct (15 cm x 20 cm) at an average velocity of 7 m/s. if the walls of the duct are maintained at 100c. a) the length of the tube for an exit temperature of the air to be 40 0c. b)the rate of heat transfer from the air. c) the fan power needed to overcome the pressure drop in this section of the duct.
Answers: 1
question
Engineering, 04.07.2019 19:10
How to increase the thermal officiency of an ideal simple rankino cycle? among these methods, which one is the best and why?
Answers: 2
question
Engineering, 04.07.2019 19:10
Estimate the change in specific internal energy au and specific enthalpy h from inlet to outlet for ethylene glycol (a liquid) flowing through each of the following devices: (a) a heat exchanger where the glycol temperature increases from 20 °c to 80 °c; (b) a pump operating at about 25 °c and increasing the glycol pressure from 100 kpa to 8 mpa.
Answers: 2