subject
Engineering, 19.03.2021 18:10 chjam265

A building has a total heating load of 200,000 Btu/hr. The sensible heat factor for the space is 0.8 and the space is to be maintained at 72 F db and 40 percent relative humidity. Outdoor air at 40 F db and 20 percent relative humidity in the amount of 1000 cfm is required. Air is supplied to the space at 120 F db and wet bulb of 76 F. Water vapor with enthalpy of 1150 Btu/lbma is used to humid- ify the air. Find a) the conditions and amount of air supplied to the space.
b) the temperature rise of the air through the furnace.
c) the amount of water vapor required.
d) the capac- ity of the furnace.

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Refrigerant 134a enters an insulated compressor operating at steady state as saturated vapor at -26°c with a volumetric flow rate of 0.18 m3/s. refrigerant exits at 9 bar, 70°c. changes in kinetic and potential energy from inlet to exit can be ignored. determine the volumetric flow rate at the exit, in m3/s, and the compressor power, in kw.
Answers: 1
question
Engineering, 04.07.2019 18:10
Afour cylinder four-stroke in-line engine has a stroke of 160mm, connecting rod length of 150mm, a reciprocating mass of 3kg and its firing order is 1-3-4-2. the spacing between cylinders is 100mm. i. show that the engine is in balance with regard to the primary inertia forces and primary 3. a and secondary inertia couples. li determine the out of balance secondary inertia force ii. propose ways of balancing this out of balance force and discuss the challenges that will arise
Answers: 3
question
Engineering, 04.07.2019 18:20
Select any two (2) areas of applications of chain-drive. (clo4) a)-permanent lubrication necessary b)-hydraulic forklift truck operation c)-rigging and heavy moving materials d)-relatively high maintenance costs e)-costlier than belt drives
Answers: 2
question
Engineering, 04.07.2019 19:10
The short distance from the objective lens to the object causes problems at high magnification. which of the following is the most serious? a. cleaning the object surface b. positioning the object c. reflection from the object surface. d. illumination of the object
Answers: 1
You know the right answer?
A building has a total heating load of 200,000 Btu/hr. The sensible heat factor for the space is 0.8...
Questions
question
Mathematics, 04.05.2021 17:40
question
History, 04.05.2021 17:40
question
Mathematics, 04.05.2021 17:40
question
History, 04.05.2021 17:40
Questions on the website: 13722361