The rate of flow through an ideal clarifier is 8000m3 /d, the detention time is 1h and the depth is 3m. If a full-length movable horizontal tray is set 1m below the surface of the water, a) determine the percent removal of particles having a settling velocity of 1m/h. b) Could the removal efficiency of the clarifier to be improved by moving the tray? If so, where should the tray be located and what would be the maximum removal efficiency? c) What effect would moving the tray have if the particle settling velocity were equal to 0.5m/h?

ansver
Answers: 1

Another question on Engineering

question
Engineering, 03.07.2019 14:10
If the thermal strain developed in polyimide film during deposition is given as 0.0044. assume room temperature is kept at 17.3 c, and thermal coefficient of expansion for the film and the substrate are 54 x 10^-6c^-1 and 3.3 x 10^-6c^-1respectively. calculate the deposition temperature.
Answers: 3
question
Engineering, 04.07.2019 18:10
Awall of 0.5m thickness is to be constructed from a material which has average thermal conductivity of 1.4 w/mk. the wall is to be insulated with a material having an average thermal conductivity of 0.35 w/mk so that heat loss per square meter shall not exceed 1450 w. assume inner wall surface temperature of 1200°c and outer surface temperature of the insulation to be 15°c. calculate the thickness of insulation required.
Answers: 3
question
Engineering, 04.07.2019 18:20
Atank with constant volume contains 2.27 kg of a mixture of water phases (liquid-vapor). in the initial state the temperature and the quality are 127 °c and 0.6, respectively. the mixture is heated until the temperature of 160 oc is reached. illustrate the process in a t-v diagram. then, determine (1) the mass of the vapor in kg at the initial state, (2) the final pressure in kpa.
Answers: 3
question
Engineering, 04.07.2019 19:20
Determine (a) the maximum thermal efficiency of reversible power cycles operating between a hot reservoir at 1000°c and a cold reservoir at 200°c and (b) the maximum cops for reversible refrigeration and heat pump cycies, respectively, between 28°c and 14°c.
Answers: 1
You know the right answer?
The rate of flow through an ideal clarifier is 8000m3 /d, the detention time is 1h and the depth is...
Questions
question
Mathematics, 11.10.2020 14:01
question
History, 11.10.2020 14:01
question
English, 11.10.2020 14:01
question
Computers and Technology, 11.10.2020 14:01
question
Mathematics, 11.10.2020 14:01
question
Mathematics, 11.10.2020 14:01
question
Mathematics, 11.10.2020 14:01
Questions on the website: 13722361