An industrial boiler consists of tubes inside of which flow hot combustion gases. Water boils on the exterior of the tubes. When installed, the clean boiler has an over all heat transfer coefficient of 300 W/m^2 . K. Based on experience, i is anticipated that the fouling factors on the inner and outer surfaces will increase linearly with time as Ra, t and Ryo-at where a, 2.5 x 10^-11 m2 K/W s and a,-1.0 x 10^-11 m^2 - K/W s for the inner and outer tube surfaces, respectively. If the boiler is to be cleaned when the overall heat transfer coeffi- cient is reduced from its initial value by 25%, how long after installation should the first cleaning be scheduled?

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
The drive force for diffusion is 7 fick's first law can be used to solve the non-steady state diffusion. a)-true b)-false
Answers: 1
question
Engineering, 06.07.2019 02:30
Air (c-1.006 kj/kg.k, r-0.287 kj/kg.k) enters a nozzle steadily at 280 kpa and 77°c with a velocity of 50 m/s and exits at 85 kpa and 320 m/s. the heat losses from the nozzle to the surrounding medium at 20°c are estimated to be 3.2 kj/kg. determine (a) the exit temperature and (b) the total entropy change for this process. solve this problem using constant specific heats.
Answers: 1
question
Engineering, 06.07.2019 02:30
1in2 processor chip can be modelled as an isothermal plane wall of silicon, isothermal on both sides. the power input to the bottom of the plane wall, or the processing power of the chip, often called the thermal design power (tdp), is 100w. assume the periphery is adiabatic. the silicon is 400 microns thick. the temperature at the junction, or in this case on the bottom of the isothermal plane wall, is 85°c. what is the top surface temperature, assuming that the only mode of heat transfer is conduction
Answers: 1
question
Engineering, 06.07.2019 03:20
An air-conditioning system consists of a heating section and an evaporative cooler. air enters the heating section at 10°c and 70 percent relative humidity at a rate of 30m^3/min, and it leaves the evaporative cooler at 20°c and 60 percent relatively humidity. if the air conditioning system operates at a total pressure of 98 kpa, determine (a) the temperature and relative humidity of the air when it leaves the heating section, (b) the rate of heat transfer in the heating section, and (c) the rate of water added to air in the evaporative cooler
Answers: 2
You know the right answer?
An industrial boiler consists of tubes inside of which flow hot combustion gases. Water boils on the...
Questions
question
Mathematics, 28.07.2019 07:30
question
Mathematics, 28.07.2019 07:30
Questions on the website: 13722363