subject
Engineering, 22.04.2021 21:20 rattler6125

The plasma concentration for a patient taking an oral drug is given by: Cp(t)=20 (e-0.2t - e-2t)
where t is in hours and Cp is in mg/L. Calculate the AUC2hr-12hr using the following methods:
(i) Analytical integration.
(ii) Sum of areas of rectangles-A. Plot Cplt) first. Then divide the time period in 5 equally spaced time intervals and calculate the sum of the areas of each of the rectangles having as base a given time interval and as height the value of Cp at the beginning of that time interval.
(iii) Sum of areas of rectangles-B. Same as in previous question, but use the value of Cp at the end of any given time interval.
(iv) Sum of areas of trapezoids using the same time intervals.
Briefly comment the differences among the results obtained above.

ansver
Answers: 3

Another question on Engineering

question
Engineering, 03.07.2019 15:10
Ahouse has the following electrical appliance usage (1) single 40w lamp used for 4 hours per day (2) single 60w fan used for 12 hours per day (3) single 200w refrigerator that runs 24 hours per day with compressor run 12 hours and off 12 hours find the solar power inverter size in watt with correction factor of 1.25.
Answers: 1
question
Engineering, 04.07.2019 18:10
Determine whether or not it is possible to compress air adiabatically from k to 140 kpa and 400 k. what is the entropy change during this process?
Answers: 3
question
Engineering, 04.07.2019 18:10
Ahot wire operates at a temperature of 200°c while the air temperature is 20°c. the hot wire element is a tungsten wire of 5 um diameter and 2 mm in length. plot using excel current, heat transfer and heat generated by the wire for air velocity varying from 1-10 m/s in steps of lm/s? matlab the sensor voltage output, resistance, or assume nu 0.989 re033pr13 take air properties at tr (200°c20°c)/2 = 110°c properties of tungsten: c 0.13 kj/kg.k 3 p 19250 kg/m k (thermal conductivity) = 174 w/m.k
Answers: 2
question
Engineering, 04.07.2019 18:10
The flow rate of air through a through a pipe is 0.02 m5/s. a pitot static tube is placed in the flow. the radius of the pitot static tube is 1 mm. assuming the flow to be steady and the air to be at 300k, calculate the difference in total and static pressure if the diameter of the pipe is: (a) d 0.1 m d 0.05 m (c) d 0.01 m
Answers: 2
You know the right answer?
The plasma concentration for a patient taking an oral drug is given by: Cp(t)=20 (e-0.2t - e-2t) <...
Questions
question
English, 02.02.2021 02:10
question
Mathematics, 02.02.2021 02:10
question
Mathematics, 02.02.2021 02:10
question
English, 02.02.2021 02:10
question
Mathematics, 02.02.2021 02:10
question
History, 02.02.2021 02:10
question
Social Studies, 02.02.2021 02:10
question
English, 02.02.2021 02:10
Questions on the website: 13722360