Electrical Engineering calculator 1 Following features are supposed to in this project:
• Equivalent resistance calculator
o Series: up to 6 resistances
o Parallel: up to 6 resistances
• Equivalent inductance calculator
o Series: up to 6 inductors
o Parallel: up to 6 inductors
• Equivalent capacitance calculator
o Series: up to 6 capacitors
o Parallel: up to 6 capacitors
• Capacitive reactance and inductive reactance calculator
o For single inductor or capacitor
• Impedance calculator for AC circuits.
o RC circuits
o RL circuits
o RLC series circuit
o RLC parallel circuit
• Finding current in a DC circuit
o Series circuit: with up to 4 resistances in circuit
o Parallel circuit: with up to 4 resistances in circuit
• Finding current in AC circuit
o RC circuits
o RL circuits

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 19:10
The proportional limit is always greater than the yield strength for a material. a)-trune b)- false
Answers: 3
question
Engineering, 04.07.2019 19:20
At steady state, air at 200 kpa, 325 k, and mass flow rate of 0.5 kg/s enters an insulated duct having differing inlet and exit cross-sectional areas. the inlet cross-sectional area is 6 cm2. at the duct exit, the pressure of the air is 100 kpa and the velocity is 250 m/s. neglecting potential energy effects and modeling air as an 1.008 kj/kg k, determine ideal gas with constant cp = (a) the velocity of the air at the inlet, in m/s. (b) the temperature of the air at the exit, in k. (c) the exit cross-sectional area, in cm2
Answers: 2
question
Engineering, 04.07.2019 19:20
Liquid flows at steady state at a rate of 2 lb/'s through a pump, which operates to raise the elevation of the liquid 100 ft from control volume inlet to exit. the liquid specific enthalpy at the inlet is 40.09 btu/lb and at the exit is 40.94 btub. the pump requires 3 btu/s of power to operate. if kinetic energy effects are negligible and gravitational acceleration is 32.174 tt/s, the heat transfer rate associated with this steady state process is most closely 1)-2,02 btu/s from the liquid to the surroundings 2)-3.98 btu/s from the surroundings to the liquid. 3)-4.96 btu/s from the surroundings to the liquid. 4)-1.04 btu/s from the liquid to the surroundings.
Answers: 2
question
Engineering, 04.07.2019 19:20
The quality is zero at a)-the saturated vapour state b)-the saturated liquid state c)-the saturated liquid-vapour mixture state d)-none of the states in the other answers
Answers: 3
You know the right answer?
Electrical Engineering calculator 1 Following features are supposed to in this project: