subject
Engineering, 02.05.2021 15:30 kimjooin02

A biomedical transducer can be represented by a series RLC circuit with a 100 ohm resistors and unknown capacitor and inductor. Analysis of the transducer in the lab indicated that the damping coefficient is 0.4 and natural resonance frequency is 159 Hz. Determine the values for the capacitive and the inductive components. Discuss the way to increase the damping coefficient to 0.707 without affecting the natural resonance frequency.

ansver
Answers: 2

Another question on Engineering

question
Engineering, 03.07.2019 14:10
The y form of iron is known as: a) ferrite b) cementite c) perlite d) austenite
Answers: 3
question
Engineering, 04.07.2019 18:10
Water in a partially filled large tank is to be supplied to the roof top, which is 8 m above the water level in the tank, through a 2.2-cm-internal-diameter pipe by maintaining a constant air pressure of 300 kpa (gage) in the tank. if the head loss in the piping is 2 m of water, determine the discharge rate of the supply of water to the roof top in liters per second.
Answers: 3
question
Engineering, 04.07.2019 18:20
Describe one experiment in which the glass transition temperature and melting temperature of a totally amorphous thermoplastic material can be determined. show the relevant experimental results in a diagram which should be properly annotated with the two temperatures clearly marked. what is likely to happen to the curve in the diagram if the amorphous polymer is replaced by a thermosetting type?
Answers: 2
question
Engineering, 04.07.2019 19:20
Liquid flows at steady state at a rate of 2 lb/'s through a pump, which operates to raise the elevation of the liquid 100 ft from control volume inlet to exit. the liquid specific enthalpy at the inlet is 40.09 btu/lb and at the exit is 40.94 btub. the pump requires 3 btu/s of power to operate. if kinetic energy effects are negligible and gravitational acceleration is 32.174 tt/s, the heat transfer rate associated with this steady state process is most closely 1)-2,02 btu/s from the liquid to the surroundings 2)-3.98 btu/s from the surroundings to the liquid. 3)-4.96 btu/s from the surroundings to the liquid. 4)-1.04 btu/s from the liquid to the surroundings.
Answers: 2
You know the right answer?
A biomedical transducer can be represented by a series RLC circuit with a 100 ohm resistors and unkn...
Questions
question
Mathematics, 18.03.2021 02:50
question
Mathematics, 18.03.2021 02:50
question
Health, 18.03.2021 02:50
question
Mathematics, 18.03.2021 02:50
Questions on the website: 13722360