subject
Physics, 26.01.2020 23:31 guitarislife97p73kzu

When looking at a food label, to be considered a good source of a nutrient, the nutrient must be? a. more than 20% of your daily recommended amount b.10-20% of your daily recommended amount c. 5% or less of your daily recommended amount

ansver
Answers: 3

Another question on Physics

question
Physics, 22.06.2019 17:00
Amajor difference radio waves, visible light, and gamma rays is the of the photons, which results in different photon frequencies and wavelengths
Answers: 1
question
Physics, 23.06.2019 01:30
The two most prominent wavelengths in the light emitted by a hydrogen discharge lamp are 656(red) and 486 (blue). light from a hydrogen lamp illuminates a diffraction grating with 500 lines per mm, and the light is observed on a screen 1.50 behind the grating. what is the distance between the first-order red and blue fringes?
Answers: 3
question
Physics, 23.06.2019 08:00
How are elastic and inelastic collisions different? give two or more ways. your answer should have at least 2 sentences.
Answers: 1
question
Physics, 23.06.2019 08:30
Atension test was conducted on a specimen of aisi 1020 hot-rolled steel having an initialdiameter of 9.11 mm. representative test data are given in table1in the form of force and engineering strain. for strain the extensometer gage length was li= 50.8 mm. in addition, minimumdiameters were measuredmanually with a micrometer in the necked region at several points during the test. after fracture, thebroken halves were reassembled, and the following measurements were made: (1) marks originally 25.4 mm apart and on opposite sides of the necked regionwere 38.6 mm apart due to the lengthwise stretching in the specimen; (2) similar marks originally 50.8 mm apart were 70.9 mmapart; (3) the final minimum diameter in the necked region was 5.28 mma) determine the following material properties: elastic modulus, 0.2% offset yield strength, ultimate tensile strength, percent elongation, and percent reduction in area. b) assume that the test was interrupted upon reaching a strain u = 0.007, and the specimen unloaded to zero force. estimate the elastic strain recovered and the plastic strain remaining. also, what would the new length of the original 50.8 mm gage section. hint: might save time/effort to use excel, mathcad, matlab, etc. to solve part a)table1 data and analysis for a tension test on aisi 1020 hot-rolled steeltest dataforce (p, kn)1. 0.002. 6.673. 13.344. 19.135. 17.796. 17.217. 17.538. 17.449. 17.2110. 20.7711. 24.2512. 25.7113. 25.7514. 25.0415. 23.4916. 21.3517. 18.9018. 17.39engr. strain (Ξ΅)1. 02. 0.00053. 0.00104. 0.00155. 0.00236. 0.00317. 0.00508. 0.00709. 0.010010. 0.049011. 0.125012. 0.218013. 0.234014. 0.306015. 0.330016. 0.348017. 0.360018. 03660diameter (d, mm)1. 9.112. 9.113. 9.114. 9.115. 9.116. 9.117. 9.118. 9.119. 9.1110. 8.8911. 8.8912. 8.2613. 8.2614. 7.6215. 6.9916. 6.3517. 5.7218. 5.28
Answers: 2
You know the right answer?
When looking at a food label, to be considered a good source of a nutrient, the nutrient must be? a...
Questions
question
Computers and Technology, 17.12.2021 02:50
question
Mathematics, 17.12.2021 02:50
Questions on the website: 13722362