subject
Physics, 12.03.2021 17:40 debrielcalderon

A large industrial exhaust fan is mounted on a steel frame in a factory. The plant manager has decided to mount a storage bin on the same platform. Adding mass to a system can change its dynamics substantially and the plant manager wants to know if this is a safe change to make. The original design of the fan support is not available. Hence measurements of the floor amplitude (horizontal motion) are made at several different motor speeds in an attempt to measure the system dynamics. No resonance is observed in running the fan from zero to 500 rpm. Deflection measurements are made and it is found that the amplitude is 10 mm at 500 rpm and 4.5 mm at 400 rpm. The mass of the fan is 50 kg and the plant manager would like to store up to 50 kg on the same platform. The best operating speed for the exhaust fan is between 400 and 500 rpm depending on the environmental conditions in the plant. Given these explanations, is it a safe practice to add the storage bin

ansver
Answers: 3

Another question on Physics

question
Physics, 22.06.2019 14:00
Ascientific blank must be testable and capable of being proven false?
Answers: 1
question
Physics, 23.06.2019 02:00
Ideal meters problem. what internal resistance is ideal for a voltmeter? what internal resistance is ideal for an ammeter?
Answers: 2
question
Physics, 23.06.2019 02:20
3. a particle with initial velocity v⃗ 0=(5.85×103m/s)j^ enters a region of uniform electric and magnetic fields. the magnetic field in the region is b⃗ =−(1.35t)k^. you can ignore the weight of the particle. a. calculate the magnitude of the electric field in the region if the particle is to pass through undeflected, for a particle of charge +0.640 nc.
Answers: 2
question
Physics, 23.06.2019 06:00
Gravity is pulling an object into the sun. the closer the object gets to the sun, the greater the gravitational force that acts on the object, increasing its acceleration. a line graph plotting the speed of the object against time would have which shape? a: straight line of positive slope b: curved line that slopes upward c: curved line that slopes downward d: straight line of negative slope
Answers: 3
You know the right answer?
A large industrial exhaust fan is mounted on a steel frame in a factory. The plant manager has decid...
Questions
question
Mathematics, 17.02.2021 01:00
question
Mathematics, 17.02.2021 01:00
question
Mathematics, 17.02.2021 01:00
question
English, 17.02.2021 01:00
question
Mathematics, 17.02.2021 01:00
Questions on the website: 13722367