subject
Engineering, 20.12.2019 05:31 jaustin1961

Aflux-cored arc-welding process is used to join two low-alloy steel plates at a 90° angle. the joint is an outside fillet weld. the plates are 1⁄4-in thick. the weld bead consists of 55% metal from the electrode and 45% from the steel plates. the heat transfer factor for fcaw = 0.9, and the melting factor = 0.65. welding current = 120 amps, and voltage = 20 volts. velocity of the welding head = 25 in/min. electrode wire diameter = 0.125 in. a core of flux (compounds that do not become part of the weld bead) runs through the center of the electrode. the diameter of the core = 0.0625 in. (a) what is the cross-sectional area of the weld bead? (b) how fast must the electrode wire be fed into the welding operation?

ansver
Answers: 1

Another question on Engineering

question
Engineering, 03.07.2019 14:10
Amass of 1.5 kg of air at 120 kpa and 24°c is contained in a gas-tight, frictionless piston-cylinder device. the air is now compressed to a final pressure of 720 kpa. during the process, heat is transferred from the air such that the temperature inside the cylinder remains constant. calculate the boundary work input during this process.
Answers: 2
question
Engineering, 04.07.2019 18:10
Water in a partially filled large tank is to be supplied to the roof top, which is 8 m above the water level in the tank, through a 2.2-cm-internal-diameter pipe by maintaining a constant air pressure of 300 kpa (gage) in the tank. if the head loss in the piping is 2 m of water, determine the discharge rate of the supply of water to the roof top in liters per second.
Answers: 3
question
Engineering, 04.07.2019 18:10
Journeyman training is usually related (clo2) a)-to specific tasks b)-to cost analysis of maintenance task c)-to control process to ensure quality d)-to installation of machinery
Answers: 2
question
Engineering, 04.07.2019 19:10
Afoot bridge is made as a simple deck, 4 m long, with a cross section 2 m (wide) and 20 cm thick, and made of wood. the deck is supported at the two ends. the maximum load allowable on the bridge is 10 tons, provided it is uniformly distributed on the deck. to sense this load, a strain gauge is placed at the center of the bridge and its resistance is monitored. if the sensor has a nominal resistance of 350 s2 and a gauge factor of 3.6, what is the reading of the strain gauge at maximum load? the modulus of elasticity for the wood used in the construction is 10 gpa.
Answers: 2
You know the right answer?
Aflux-cored arc-welding process is used to join two low-alloy steel plates at a 90° angle. the joint...
Questions
question
Chemistry, 07.10.2020 21:01
question
Mathematics, 07.10.2020 21:01
question
Mathematics, 07.10.2020 21:01
question
Chemistry, 07.10.2020 21:01
Questions on the website: 13722359