There are two ingredients (A and B) that will be mixed in the reactor tank. Wait for READY signal to be on (when on, it signifies that QA Tank is ready for this batch). 2. To add the fixed amount of ingredient A to the mixing tank, VALVE_A needs to be on. To add the fixed amount of ingredient B to the mixing tank, VALVE_B needs to be on. Both VALVE_A and VALVE_B will be turned on for 10 seconds, then they need to be turned off automatically. 3. When material A is ready to be added, PULSE_A will be on. When material B is ready to be added, PULSE_B will be on. If the PULSE_A for material A (or PULSE_B for material B) is off, the material A cannot be added to the mixing tank even the VALVE_A is turned on. 4. After the materials are fed into the mixing tank, agitate and mix the materials at a high speed (500 rpm) by turning on the motor AGIT_ON_HS for 20 seconds. 5. After that, the agitate motor is then switch for a lower speed (200 rpm) by turning on the motor AGIT_ON_LS for 30 seconds.
Answers: 1
Engineering, 04.07.2019 18:10
Which one from below is not one of the reasons of planning failures? (clo3) a)-planner is careless. b-planner spend less time in the field but more time on the desk c)-planner is not qualified d)-planner does not have sufficient time to properly plan
Answers: 3
Engineering, 04.07.2019 18:10
Awall of 0.5m thickness is to be constructed from a material which has average thermal conductivity of 1.4 w/mk. the wall is to be insulated with a material having an average thermal conductivity of 0.35 w/mk so that heat loss per square meter shall not exceed 1450 w. assume inner wall surface temperature of 1200°c and outer surface temperature of the insulation to be 15°c. calculate the thickness of insulation required.
Answers: 3
Engineering, 04.07.2019 19:10
With increases in magnification, which of the following occur? a. the field of view decreases. b. the ambient illumination decreases. c. the larger parts can be measured. d. the eyepiece must be raised.
Answers: 1
Engineering, 05.07.2019 23:20
Which one of the following faults cause the coffee in a brewer to keep boiling after the brewing cycle is finished? a. an open circuit in the heating element b. a short circuit at the terminals c. welded contacts on the thermostat d. a leak around the gasket
Answers: 3
There are two ingredients (A and B) that will be mixed in the reactor tank. Wait for READY signal to...
Mathematics, 24.01.2021 19:00
English, 24.01.2021 19:00
Mathematics, 24.01.2021 19:00
History, 24.01.2021 19:00
Mathematics, 24.01.2021 19:00
English, 24.01.2021 19:00
Mathematics, 24.01.2021 19:00
Engineering, 24.01.2021 19:00
Mathematics, 24.01.2021 19:00
Mathematics, 24.01.2021 19:00
Mathematics, 24.01.2021 19:00
Mathematics, 24.01.2021 19:00
Mathematics, 24.01.2021 19:00
Biology, 24.01.2021 19:00