subject
Engineering, 20.04.2020 23:50 esigaran24

A heat pump with refrigerant-134a as the working fluid is used to keep a space at 25°C by absorbing heat from geothermal water that enters the evaporator at 60°C at a rate of 0.415 kg/s and leaves at 40°C. The refrigerant enters the evaporator at 12°C with a quality of 15 percent and leaves at the same pressure as saturated vapor. The compressor consumes 1.6 kW of power. Use data from the tables.

If the compressor consumes 1.6 kW of power, determine
(a) the mass flow rate of the refrigerant,
(b) the rate of heat supply,
(c) the COP, and
(d) the minimum power input to the compressor for the same rate of heat supply.

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Air is to be cooled in the evaporator section of a refrigerator by passing it over a bank of 0.8-cm-outer-diameter and 0.4-m-long tubes inside which the refrigerant is evaporating at -20°c. air approaches the tube bank in the normal direction at 0°c and 1 atm with a mean velocity of 4 m/s. the tubes are arranged in-line with longitudinal and transverse pitches of sl- st 1.5 cm. there are 30 rows in the flow direction with 15 tubes in each row. determine (a) the refrigeration capacity of this system and (b) pressure drop across the tube bank. evaluate the air properties at an assumed mean temperature of -5°c and 1 atm. is this a good assumption?
Answers: 1
question
Engineering, 04.07.2019 18:10
Thermal stresses are developed in a metal when its a) initial temperature is changed b) final temperature is changed c) density is changed d) thermal deformation is prevented e) expansion is prevented f) contraction is prevented
Answers: 2
question
Engineering, 04.07.2019 18:10
Atmospheric air has a temperature (dry bulb) of 80° f and a wet bulb temperature of 60° f when the barometric pressure is 14.696 psia. determine the specific humidity, grains/lb dry air. a. 11.4 c. 55.8 d. 22.5 b. 44.1
Answers: 1
question
Engineering, 04.07.2019 18:20
Find the kinematic pressure of 160kpa. for air, r-287 j/ kg k. and hair al viscosity of air at a temperature of 50°c and an absolute (10 points) (b) find the dynamic viscosity of air at 110 °c. sutherland constant for air is 111k
Answers: 3
You know the right answer?
A heat pump with refrigerant-134a as the working fluid is used to keep a space at 25°C by absorbing...
Questions
question
Mathematics, 11.03.2021 18:50
question
Mathematics, 11.03.2021 18:50
question
Mathematics, 11.03.2021 18:50
question
Mathematics, 11.03.2021 18:50
question
Mathematics, 11.03.2021 18:50
question
Mathematics, 11.03.2021 18:50
question
Computers and Technology, 11.03.2021 18:50
Questions on the website: 13722359