Consider the cross-sectional view of two, infinitely long, conductors shown below. The top conductor, located at =4
z
=
4
=4
z
=
4
has a current density of
βƒ—1=^4A/m2
J
β†’
1
=
a
x
^
4
A/m
2
βƒ—1=^4A/m2
J
β†’
1
=
a
x
^
4
A/m
2
and a radius of 1m. The lower conductor, located at
=βˆ’4
z
=
βˆ’
4
=βˆ’4
z
=
βˆ’
4
, has a current density of
βƒ—2=βˆ’^16A/m2
J
β†’
2
=
βˆ’
a
x
^
16
A/m
2
βƒ—2=βˆ’^16A/m2
J
β†’
2
=
βˆ’
a
x
^
16
A/m
2
and a radius of 0.5m.

What is the magnitude and direction of the magnetic field at (0, 0, 0)?

ansver
Answers: 2

Another question on Engineering

question
Engineering, 03.07.2019 15:10
Heat is added to a piston-cylinder device filled with 2 kg of air to raise its temperature 400 c from an initial temperature of t1 27 cand pressure of pi 1 mpa. the process is isobaric process. find a)-the final pressure p2 b)-the heat transfer to the air.
Answers: 1
question
Engineering, 04.07.2019 18:10
Water in a partially filled large tank is to be supplied to the roof top, which is 8 m above the water level in the tank, through a 2.2-cm-internal-diameter pipe by maintaining a constant air pressure of 300 kpa (gage) in the tank. if the head loss in the piping is 2 m of water, determine the discharge rate of the supply of water to the roof top in liters per second.
Answers: 3
question
Engineering, 04.07.2019 18:10
The flow rate of air through a through a pipe is 0.02 m5/s. a pitot static tube is placed in the flow. the radius of the pitot static tube is 1 mm. assuming the flow to be steady and the air to be at 300k, calculate the difference in total and static pressure if the diameter of the pipe is: (a) d 0.1 m d 0.05 m (c) d 0.01 m
Answers: 2
question
Engineering, 04.07.2019 18:20
Athin walled concentric tube exchanger is used to cool engine oil from 160Β°c to 60Β°c with water that is available at 25Β°c acting as a coolant. the oil and water flow rates are each at 2 kg/s, and the diameter of the inner tube is 0.5 m and the corresponding value of the overall heat transfer coefficient is 250 w/m2. oc. how long must the heat exchanger be to accomplish the desired cooling? cpwater=4.187 kj/kg-candcpengine el=2.035 kj/kgΒ·Β°c, oil . 120]
Answers: 1
You know the right answer?
Consider the cross-sectional view of two, infinitely long, conductors shown below. The top conductor...
Questions
question
Computers and Technology, 21.11.2019 03:31
question
Business, 21.11.2019 03:31
question
Business, 21.11.2019 03:31
question
Mathematics, 21.11.2019 03:31
Questions on the website: 13722361