Rods of radioactive waste that are highly active are stored in cooling ponds of purified water. Usually, the rods are stored 20 feet below the surface of the water. We wish to calculate the neutron flux that reaches the surface of the water. The total cross-section for an incident, room-temperature neutron onto a 1H nucleus is approximately 35 barns. The total cross-section for an incident, room-temperature neutron onto an oxygen nucleus is approximately 4 barns A. Calculate the molecular number density of water.
B. Calculate the number density of hydrogen nuclei and the number density of oxygen nuclei.
C. Calculate the macroscopic cross-section (Z) for an incident, room temperature neutron passing through the water.
D. Calculate the mean free path ( (x) ) of a room temperature neutron in water.
E. Calculate the fraction of the radiation emitted from the rods that reach the surface of the water (1(x)/10).

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Adouble-strand no. 60 roller chain is used to transmit power between a 13-tooth driving sprocket rotating at 300 rev/min and a 52-tooth driven sprocket. a) what is the allowable horsepower of this drive? b) estimate the center-to-center distance if the chain length is 82 pitches. c) estimate the torque and bending force on the driving shaft by the chain if the actual horsepower transmitted is 30 percent less than the corrected (allowable) power.
Answers: 3
question
Engineering, 04.07.2019 18:10
The higher the astm grain-size number, the coarser the grain is. a)-true b)-false
Answers: 3
question
Engineering, 04.07.2019 18:10
An air compression refrigeration system is to have an air pressure of 100 psia in the brine tank and an allowable air temperature increase of 60°f for standard vapor compression cycle temperatures of 77 f entering the expansion cylinder and 14 f entering the compression cylinder, calculate the coefficient of performance a. 2.5 b 3.3 c. 4.0 d. 5.0
Answers: 3
question
Engineering, 04.07.2019 18:20
Athin walled concentric tube exchanger is used to cool engine oil from 160°c to 60°c with water that is available at 25°c acting as a coolant. the oil and water flow rates are each at 2 kg/s, and the diameter of the inner tube is 0.5 m and the corresponding value of the overall heat transfer coefficient is 250 w/m2. oc. how long must the heat exchanger be to accomplish the desired cooling? cpwater=4.187 kj/kg-candcpengine el=2.035 kj/kg·°c, oil . 120]